文章摘要
AA3型连续流动分析仪与钒钼黄比色法测定玉米植株全磷含量之比较
Determination Total Phosphour of Maize Plant Samples by Continuous Flow Analyzer in Comparison with Vanadium Molybdate Yellow Colorimetric Method
投稿时间:2015-01-29  
DOI:10.13254/j.jare.2015.0030
中文关键词: 连续流动分析仪  钒钼黄比色法  植物全磷
英文关键词: continuous flow analyzer (CFA)  vanadium molybdate yellow colorimetric method (VMYC method)  plant phosphorus
基金项目:国家重点基础研究发展计划(“973”计划)项目(2013CB127402);中央级公益性科研院所专项资金资助项目(IARRP-2014-39)
作者单位E-mail
刘云霞 中国农业科学院农业资源与农业区划研究所/耕地培育技术国家工程实验室/农业部植物营养与肥料重点实验室, 北京 100081  
温云杰 中国农业科学院农业资源与农业区划研究所/耕地培育技术国家工程实验室/农业部植物营养与肥料重点实验室, 北京 100081  
黄金莉 中通科技发展有限公司, 北京 100088  
李桂花 中国农业科学院农业资源与农业区划研究所/耕地培育技术国家工程实验室/农业部植物营养与肥料重点实验室, 北京 100081  
柴晓 中国农业科学院农业资源与农业区划研究所/耕地培育技术国家工程实验室/农业部植物营养与肥料重点实验室, 北京 100081  
汪洪 中国农业科学院农业资源与农业区划研究所/耕地培育技术国家工程实验室/农业部植物营养与肥料重点实验室, 北京 100081 wanghong01@caas.cn 
摘要点击次数: 2899
全文下载次数: 2799
中文摘要:
      选择69个玉米秸秆和籽粒样品,经浓H2SO4和H2O2消煮后,用连续流动分析仪与钒钼黄比色法分别测定消煮液中磷含量,对2种方法检测数据之间进行比较分析,探讨利用连续流动分析仪测定植株样品消煮液中磷含量的可行性。t检验表明:2种方法测定植株全磷含量相比无明显差异。测定结果之间呈显著线性相关系,回归直线方程为Y(连续流动分析仪-P)=0.927X(钒钼黄比色法-P)-0.002,相关系数r=0.985(n=69,P<0.01)。连续流动分析仪测定加标回收率在99.3%~103.8%之间,对4个样品消煮液中磷浓度分别重复测定10次,相对标准偏差小于1.5%。连续流动分析仪分析速度快,消耗试剂少,推荐用于大批量玉米植株样品H2SO4-H2O2消煮液中磷含量分析。
英文摘要:
      The vanadium molybdate yellow colorimetric method(VMYC method) is regarded as one of conventional methods for determining total phosphorus(P) in plants, but it is time consuming procedure. Continuous flow analyzer(CFA) is a fluid stream segmentation technique with air segments. It is used to measure P concentration based on the molybdate-antimony-ascorbic acid method of Murphy and Riley. Sixty nine of maize plant samples were selected and digested with H2SO4-H2O2. P concentrations in the digests were determined by CFA and VMYC method, respectively. The t test found that there was no any significant difference of the plant P contents measured by the CFA and the VMYC method. A linear equation could best describe their relationship: Y(CFA-P)=0.927X(VMYC-P)-0.002. The Pearson's correlation coefficient was 0.985 with a significance level(n=69, P<0.01). The CFA method for plant P measurement had a high precision with relative standard deviation(RSD) less than 1.5%. It is suggested that the CFA based on Murphy and Riley colorimetric detection can be used to determinate total plant P in the digests solutions with H2SO4-H2O2. The CFA method is labor saving and can handle large numbers of samples. The human error in mixing with other operations is reduced to a great extent.
HTML   查看全文   查看/发表评论  下载PDF阅读器
关闭